Normal 410a pressures - Although it's really impossible to say what the "normal operating pressures" are for an R410A system as it's based on so many variables:load, humidity, condition of outdoor coil (clean or dirty), I would expect to see 120-135 on the low side and about 280-300 on the high side. Again, these are just examples.

 
Currently working on a Bremar ice maker. Just did a compressor change and thought I weigh charged it perfectly. But it's not making good ice. I have only a suction port to read the pressures, and I'm getting 300kpa at the beginning of the 8.5 min cycle, and around 240kpa by the end. It runs for 8.5miutes then goes on defrost to drop the ice made.. Cvs prudential center

system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3.Looking for normal operating pressure/temps for r-410. 14.5 seer, 2.5t new unit. 83deg outside, system was running @ 255# high side, 135#low side, liquid line temp was 84deg. Suction line temp was 64deg. I know these pressures are low, can unit be ran until weekend is over? I think undercharged? At the time house thermostat was at 78deg. Inside and set for 72 deg. Temp coming out of register ...Degree, Mech Engr Techno... 13,006 satisfied customers. Gonna charge a 3 ton heatpump with R410a on a 68 degree. Gonna charge a 3 ton heatpump with R410a on a 68 degree ambient that has a 3/8 by 7/8 lineset of 25 ft what should my pressures be close to if … read more.r-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3It is a clear, colorless, non-toxic and non-irritating liquid. R-410A is a 50:50 blend of R-32 and R-125. The boiling point at atmospheric pressure is -62.9°F. A few of the important principles that make the refrigeration cycle possible …404R pressure temperature chart is quite simple to understand. This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, the pressure of 404A is 456.8 psig. We are, of course, talking about 404A liquid pressure.This guideline obviously doesn't work on an R-410A system or any other refrigerant. ... A dirty condenser coil would cause the suction pressure to drop below normal. It may also cause superheat problems. Once heat mode a charge is set, whether by manufacturer specification or an alternative method, you can still verify the subcool and …22 feb 2020 ... What should my normal operating pressures on 410a systems be? R410a suction pressure may be around 120psi, and R410a head pressure may be ...Buy PT Chart R22/R-410A Laminated Pocket Aid Pressure/Temperature # 34-3400-02: First Aid Kits - Amazon.com ✓ FREE DELIVERY possible on eligible purchases.If the duct system was designed for a required airflow for heating of 1,065 cfm at a 0.3 external static pressure (ESP in inches of water column [IWC]) it would draw 154 Watts. However, the cooling system requires 1,300 cfm, which increases the static pressure to slightly above 0.4 ESP and increase the operating wattage to slightly over 179 watts.What are normal operating pressures for 410A mini split? The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. However, it should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load.Need a model number for more information on the ice machine, for proper pressures for the system, but the service manual will tell you. But it sounds like the right answer, 75% of the charge for an ice machine is needed for harvesting, you can be very low on refrigerant and you'll still make ice.86°F. Any Tecumseh compressor with the letter “C” in the Model Number (Example: AWG5528CXD) is approved for use with R407C. shown in Figure 1. properties of R407C and R22. The data is taken at the standard refrigerant conditions of 5°F (-15°C) evaporating or 86°F (+30°C) condensing.What is the standing and discharge pressure of a refrigerant? Refrigerant pressure readings R-22, R-410A, R-290, R-417A 1 Standing pressure – 150 PSI 2 Saction pressure – 60 TO 70 PSI 3 Discharge pressure – 250 TO 300. Freon gas standing and working pressure ( R32, R410A, R502,R407C, R134A etc ) Watch on. Previous article.Use a pressure conversion chart to change the high side pressure to saturated temperature. Deduct the liquid-line temperature from the saturation temperature of R-410A refrigerant in the condenser to compute the sub-cooling value. On the manufacturer's data sheet find the correct operating pressures for the circumstances …*Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R407A (psig)* Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Created Date: 12/31/2018 2:20:06 PM ...psig °f psig °f psig °f psig °f psig °f 12; -37.7. 114In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...psig °f psig °f psig °f psig °f psig °f 12; -37.7. 114410a ductless mini split operating pressures. I know that you should rarely put gauges on a ductless mini split, and that you should dump the charge and just weigh it in. I have heard that there are spec sheets that will give you "normal operating pressures" based on indoor and outdoor conditions. This would come in handy when servicing …This HVAC Video is about what the Normal Operating Pressures are for Freon R22 and R410A Refrigerants. I go over what affects the pressures on the low side and the high side, the saturation state pressures and temperatures, what too low of a pressure means on the vapor side and what too high of a pressure means on the liquid line.86°F. Any Tecumseh compressor with the letter “C” in the Model Number (Example: AWG5528CXD) is approved for use with R407C. shown in Figure 1. properties of R407C and R22. The data is taken at the standard refrigerant conditions of 5°F (-15°C) evaporating or 86°F (+30°C) condensing.What should my normal operating pressures on 410a systems be?. Btw ... pressures with Temperature Pressure chart to obtain required pressures Notes:. if i ...barg. Used to describe R410A gauge pressure; it’s commonly referred to as “2-bar gauge pressure” in HVAC literature. psig. Pounds Per Square Inch (psig) is most commonly used to express pressure levels at a specific temperature for R410A refrigerant. In universal units, 1 psi equals to about 6895 N/m 2.What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system. What is the normal discharge ...r410a high/low pressures. Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold.Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ... common refrigeration expertise in determining the correct operating pressures, based on the actual conditions. Ind. Title: Temperature-Pressure Chart.xlsxSep 17, 2017 · Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock out compressor, run air handler fan only. However, in order to know the proper pressure, you also need to identify the correct corresponding temperature. The chart below helps you know what pressure R404a should run at. R404a Refrigerant Pressure Chart. Temperature (Fahrenheit) Temperature (Celsius) R404a Pressure – 50°F – 45.6°C: 0.1 psi – 45°F – 42.8°C: 2 psipressures and refrigeration capacity than R-22. The compositions of Freon™ 407C and Freon™ 410A are as follows: HFC-32 HFC-125 HFC-134a Freon™ 407C (R-407C), wt% 23 25 52 Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of theRe: Mini Split Recharge R410a by pressure? it aint perfect, it aint right... but itll be fine. the charge should always be weighed in with new 410a, but now its done i wouldnt expect anyone is instructing the OP to revisit site, recover that system and weigh in new refrigerant. 850kpa is about right for splits in normal conditions.Generally, you will see normal superheat (8°-14°) on a system with heat mode TXV, and the subcooling will generally be a bit higher than usual, especially when measured outside. Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system.HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is Calculated. This...The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.As an HVAC technician or someone interested in air conditioning systems, understanding the key factors that impact 410A refrigerant pressures is crucial. The proper functioning of an air conditioning unit relies on maintaining the correct r...High suction pressure normal head pressure: When the refrigerant is flowing in the suction line from the compressor to evaporator coil without any leakage or damaging the compressor’s piston and also there no impurities are present then the pressure range will be inside the system is 0.75 – 1.3 MP ,this called the High suction pressure normal …A small amount of refrigerant will come out, which is normal; simply attach the hoses as quickly as possible to minimize the loss. Turn the R410 Tank valve to on. Flip the box of R410a upside down so the liquid will flow into the unit instead of vapor. With the mini split on and working, check the blue gauge pressure.What is the normal suction pressure and discharge pressure of or freon R22 compressor. With 90 F outdoor temperature and 79 F indoor temperature you can expect a 120 F condensing temperature, (ambient plus 30). 90 F + 30 F = 120 F ; Convert temperature to pressure, R 22 at 120 F = 260 psi ; Indoor temperature (70 F) minus 40 F …What are normal operating pressures for 410A in cooling mode? During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. What pressure should 410A be at 80 degrees? R-410A Pressure Temperature Chart What is the pressure of R-410A at 30 degrees F? R-410A Pressure Temperature ChartTurn the thermostat to cool and set the target temperature at least 10 degrees lower than the indoor temperature. Let the system operate for at least 10 minutes to let pressures equalize. Record the suction line pressure. Use a temperature measuring device to measure the temperature of the suction line.18 PRESSURE (PSIG) Sat. Temp (°F) R-22 R-407C Liquid Pressure R-407C Vapor Pressure R-410A Liquid Pressure R-427A Liquid Pressure R-427A Vapor Pressure R-407A LiquidWhat is the higher pressure of R-410A? Normally R-22 operating system typically have a high-side (discharge) pressure of 260 psig and low-side (suction) …Refrigerants come in three classifications: high pressure (R-22, R-407C, and R-410A), medium pressure (R-134A), and low pressure (R-123). The high-pressure and medium- ... 1 for kW/ton vs. percent of part load for typical scroll, screw, and centrifugal chillers). These values were incorporated into IPLV equation, which is: Enlarge this picture ...SUBJECT: TEMPERATURE - PRESSURE CHART FOR FYI #289 9/17/2009 R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS ADVANTAGE Engineering, Inc.525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 web site: www.AdvantageEngineering.com email: [email protected] Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners and heat pump systems. Additionally, it widely replaces HCFC R-22 which was mandated by …Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:...What are normal operating pressures for 410A on a 70 degree day? The operating pressure of 410A on a 70 degree day is 201.5 psig. What should my AC …In this HVAC Training Video, I show the Step By Step Procedure for Charging R-410A Refrigerant into an Air Conditioner that is Low on Refrigerant. I show the...Check Pages 1-2 of normal refrigerant pressures for 404a ice machine in the flip PDF version. normal refrigerant pressures for 404a ice machine was published by Inez Powers on 2018-06-20. ... R-410A is potentially the most efficient refrigerant atmedium-temperature conditions (0 to 30 degrees F).Jan 15, 2023 · What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system. What is the normal discharge ... Another significant difference between R-410A and R-22 is its saturation pressure range. R-410A has a higher pressure range curve than R-22. Remember, R-410A is a near azeotrope that is subject to some fractionation. At any specific temperature it has a higher vapor pressure than R-22 when saturated. R-410APractical Applications of the Subcooling Chart 410a. System Troubleshooting and Diagnostics. Identifying Overcharge or Undercharge Issues. Detecting Refrigerant Leaks. Assessing System Efficiency. System Maintenance and Optimization. Adjusting Refrigerant Charge. Evaluating Expansion Valve Performance. Balancing System Capacity.May 20, 2021 · The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system. What are normal pressures for R-410A? Mini split manufacturers have been saying that since befrore R410A came out. All the old R22 units told you to weigh in charge only. And nobody is going to do that. It's like an quick change oil place telling customers that their engines have to be pulled and weighed to check their oil levels. No, its not the same.by High Performance HVAC | Refrigeration | 0 comments Table of Contents Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners and heat pump systems.I installed a new 410a complete system with new Orfice coil and new lineset. 70 degrees on install date and initial start up. Suction pressure was 110 and high side of 280. It ran for about 15 minutes. I added a little freon and the high side shot up to 425.Jul 4, 2015 · Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation. Looking for normal operating pressure/temps for r-410. 14.5 seer, 2.5t new unit. 83deg outside, system was running @ 255# high side, 135#low side, liquid line temp was 84deg. Suction line temp was 64deg. I know these pressures are low, can unit be ran until weekend is over? I think undercharged? At the time house thermostat was at 78deg. Inside and set for 72 deg. Temp coming out of register ...Consider the refrigerant R-410A: the pressure in the evaporator is 93.2 psia, according to the Table 8 (ASHRAE, 2013). The pressure value is used to find the saturation temperature. ... a lower temperature in the pipes means that the moisture contained in the air is going to freeze even if we have a normal airflow supplied by the blower. Even ...Jan 14, 2020 · R22 gauge pressure is 10.9 bar or 158.2 psi. High side pressure typically varies by equipment and metering controls. Low pressure or suction side typically varies by equipment. Low-pressure refrigerant turns on the carrier HVACR at 50 psi (R22 pressure at 30 degrees) and closes at 100 psi (R22 pressure at 85 degrees). HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is Calculated. This...COMPARISON OF R-407C AND R-410A WITH R-22 IN A 10.5 kW (3.0 TR) RESIDENTIAL CENTRAL HEAT PUMP ... with compressor capacities and system pressures temperatures that are similar. The major difference of R-407C is that it has a temperature glide about 6°C (1 0.8°F) for typical air~ conditioning evaporating temperatures. R-41 OA however, …Sep 17, 2017 · Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock out compressor, run air handler fan only. Practical Applications of the Subcooling Chart 410a. System Troubleshooting and Diagnostics. Identifying Overcharge or Undercharge Issues. Detecting Refrigerant Leaks. Assessing System Efficiency. System Maintenance and Optimization. Adjusting Refrigerant Charge. Evaluating Expansion Valve Performance. Balancing System Capacity.Generally, you will see normal superheat (8°-14°) on a system with heat mode TXV, and the subcooling will generally be a bit higher than usual, especially when measured outside. Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature …R22 alternative names: CHClF 2 Chlorodifluoromethane, Difluoromonochloromethane, generic term: hydrochlorofluorocarbon (HCFC) R22 boiling point: -40.8 degree Celsius at atmospheric pressure (sea level or 1 ATM) R22 density: 3.66 g/cm 3, in gas form - this is a colorless gas. R22 molar mass: 86.47 g/mol.A normally operating R-410A system with the same condensing temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side …compressor ZP42 (R410A) has been analyzed. 2 3 Pure Compressor Analysis: R410A and R407C show very similar performances with a slight advantage of R407C at higher pressure ratio, i.e. condition 2 and 3 in the above graphs. R410A compressors operate with a higher discharge temperature and therefore utilize unique engineering solutions to …Matthew: The low side pressure when the compressor is running is a feature of the compressor's own pumping power combined with the properties of whatever device is being used to meter refrigerant into the system. That creates the pressure drop between high and low sides. The actual pressure when the system is running depends on.R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 – 02/22. Created Date: 2/25/2022 1:24:53 PM ...This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, ... R410A PT Chart: -60°F To +155°F Pressure Temperature Chart; R22 PT Chart: Pressure Temperature Chart For -60°F To +155°F; R454B PT Chart: Pressures At -40°F To 150°F ...Refrigerants - Pressure vs. Temperature Charts Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Refrigerants - Saturation Pressures vs. Temperatures Temperature and pressure diagram for constant boiling refrigerants - imperial and SI units. Triple Points Substancesr410a high/low pressures. Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold.equipment or components on R-410A equipment. Ensure service equipment is rated for R-410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants. Wear safety glasses and gloves to prevent personal injury. During normal system operations, some components are hot and can ...What is the normal suction pressure and discharge pressure of or freon R22 compressor. With 90 F outdoor temperature and 79 F indoor temperature you can expect a 120 F condensing temperature, (ambient plus 30). 90 F + 30 F = 120 F ; Convert temperature to pressure, R 22 at 120 F = 260 psi ; Indoor temperature (70 F) minus 40 F …Jun 7, 2014 · Mini split manufacturers have been saying that since befrore R410A came out. All the old R22 units told you to weigh in charge only. And nobody is going to do that. It's like an quick change oil place telling customers that their engines have to be pulled and weighed to check their oil levels. No, its not the same. This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, ... R410A PT Chart: -60°F To +155°F Pressure Temperature Chart; R22 PT Chart: Pressure Temperature Chart For -60°F To +155°F; R454B PT Chart: Pressures At -40°F To 150°F ...Certified HVAC Technician/... 38 satisfied customers. I have a Goodman electric heat pump. 1. When set to cool, I have a Goodman electric heat pump. 1. When set to cool, the indoor status blinks for normal operation (2 seconds on and 2 seconds off) 2. When set to … read more.Saturation Pressure-Temperature Data for R410A (psig)* *Red Italics Indicate Inches of Mercury Below Atmospheric PressureWhile a blood pressure of 120/80 is normal for people over 18, for those under age 18, normal is based on a percentile rating for the teen’s age, height and gender, according to KidsHealth. A blood pressure above the 90th percentile is out ...We would like to show you a description here but the site won’t allow us.Jun 12, 2023 · High Head Pressure, Normal Suction Pressure . High Head Pressure, Normal Suction Pressure is a common problem that can occur in an air conditioning system. It occurs when the compressor’s condensing unit has difficulty turning the refrigerant from gas to liquid because of high outside temperatures or inadequate airflow through the outdoor coil. Consider the refrigerant R-410A: the pressure in the evaporator is 93.2 psia, according to the Table 8 (ASHRAE, 2013). The pressure value is used to find the saturation temperature. ... a lower temperature in the pipes means that the moisture contained in the air is going to freeze even if we have a normal airflow supplied by the blower. Even ...base-valve service ports. Run system at least 10 minutes to allow pressure to stabilize. 2. For best results, temporarily install a thermometer on the suction line near the compressor. The thermometer should be located within 4” to 6” of the compressor. Ensure the thermometer makes adequate contact and is insulated.Lets assume we’re connected to the R-22 heat pump system below running in the cool cycle, measuring pressures, tubing temps and calculating superheat and subcooling. So, we’re looking at a head pressure of 225 psi, a suction pressure of 75 psi, liquid line temp @ 100F and suction line temp @ 55F. If we convert the head and suction pressures ...

Apr 22, 2020 · Most technicians in the HVAC field know the normal range of operation for the low-pressure side of an air conditioning system. This tends to be around 60 PSI to 85 PSI for R-22 and 105 PSI to 143 PSI for R-410A and is dependent upon operating conditions. On the high-pressure side of the system, there is a wide variation in pressure due to the wide outdoor temperature swing and due to the ... . Project zomboid everyone's infected

normal 410a pressures

What is the suction pressure of a Mitsubishi R410a? Normally R-22 operating system typically have a high-side (discharge) pressure of 260 psig and low-side (suction) pressure of 76 psig, while a normally R-410A operating system have a high-side (discharge) pressure of 418 psig and low-side (suction) pressure of 130 psig at 45°F/7.2℃.Connect the gauges center yellow hose to the R410a refrigerant tank. Connect the adapter to the blue low pressure line on the gauges. As quickly as possible, attach the blue hose with the adapter to the mini split port. A small amount of refrigerant will come out, which is normal; simply attach the hoses as quickly as possible to minimize the loss.Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...Apr 14, 2021 · Normal R-22 systems operate with high pressure of about 260 psi at 120° temperature and low pressure of about 76 psi at 45° evaporator temperature. R-410A. R-410 is also known as “Puron.” This refrigerant is recommended for use in new residential AC units. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners and heat pump systems. Additionally, it widely replaces HCFC R-22 which was mandated by …The normal pressure for a typical R-401A mini-split ranges from 110-140 psi. However, keep in mind that the working pressure depends on factors like cooling load and weather. According to experts, the working pressure should never be less than 100 psi or more than 160 psi.Measure the outdoor temperature in the shade entering the condenser. 3. ADD the CTOA (Condensing Temperature Over Ambient) based on the SEER rating, age or prior benchmarks. 4. Subtract the nameplate subcooling or 10 degrees if there is no nameplate. 5. Compare to the liquid line temperature.OPERATING PRESSURE POINTS "Systems using R-410A operate at higher pressures [than R-22]," points out the Field Diagnostics team. "For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ...Hey guys- heading back out tomorrow on a no cool call back. First call found pressures (410A) 110/655. ID temp around 78 and OD temp 97. Cleaned condenser and got head to drop down around 475 with fluctuations up to 495.This script determines the gas pressure based on temperature of R410a refrigerant. R410A is an HFC refrigerant, invented by Honeywell, that has been developed to replace the HCFC refrigerant R22. Systems operating on R410A run at a pressure of about 1.6 times that of similar systems operating on R22. Energy efficiency is comparable to R22.The human heart creates a pressure within the circulatory system every time it beats. Some people experience periods where their blood pressure is too high or too low. When blood Maintaining normal blood pressure levels is an important part....